EAC certificate for customsResponse within 24 hours.Russian Language Support
Description
Normally closed smoke exhaust valve is designed for smoke-control ventilation systems in buildings. In normal mode it is closed; in case of fire, upon a signal from fire automation, it is opened by an electric actuator to remove smoke. A fusible link lock at 280°C disconnects the actuator and closes the valve when the limiting temperature is reached. Cabinet-type housing made of galvanized steel 2.0 mm, high-temperature version. Fire resistance E 600 (600°C for 60 minutes).
Technical Specifications
Parameter
Value
Size
200×200 – 2000×1000 mm
Activation Temperature
280°C
Fire Resistance
E 600 (EN 1366-2)
Actuator
Electric 230V/24V, reversible
Airflow
2000 – 60000 m³/h
Certification
CCCF, CE, EAC
FAQ
The most frequent questions from engineers and clients — with specific answers.
Will the smoke withstand 280°C?
Yes. Execution E 600 per EN 1366-2: withstands 600°C for 60 minutes without loss of tightness. Fusible link lock 280°C — this is protection against actuator overheating; at 280°C the damper closes automatically. This is a requirement of all fire safety regulations.
How to synchronize with the fire alarm system?
The valve has a terminal box with contacts: power supply 230V/24V, opening signal, closing signal, feedback (limit switches). It connects to any fire alarm control panel (FACP). We attach the wiring diagram in Russian.
Can it be opened manually when the power is disconnected?
Yes. The actuator has a manual open/close handle. In case of fire and power outage, duty personnel can open the valve manually. There is also a version with a battery-powered actuator (up to 72 hours of autonomous operation).
How does it differ from a standard fire damper rated at 70°C?
Valve 70°C — normally open, installed on standard ventilation systems, CLOSES in case of fire. Valve 280°C — normally closed, installed on SMOKE EXTRACTION systems, OPENS in case of fire to remove smoke, and closes at 280°C. These are two different devices for different systems.
Quantity Calculation
Not just parameters — but how many units are needed for typical facilities.
Business center with smoke extraction
24-32 pcs
For Smoke Exhaust Systems
Underground Parking
16-24 pcs
Parking Smoke Extraction System
Shopping Center
40-60 pcs
Evacuation zones, atriums
Industrial Building
12-20 pcs
Shops with category A/B
Need an accurate calculation for your project? Send us a building plan or ventilation calculation — an engineer will calculate the quantity and select models for free within 24 hours.
Customs Documentation
Full package of documents for hassle-free customs clearance in EAEU countries.
EAC certificate TR CU 004/2011 + TR CU 020/2011
CE declaration EN 1366-2, EN 12101-8
CCCF certificate
E 600 Test Protocol
Certificate of Origin
Packing list, invoice
Connection diagram, passport
All documents are provided in Russian with the manufacturer's stamp. Certificates are valid in Kazakhstan, Belarus, Armenia, Kyrgyzstan, and Russia.
Production & Delivery
Standard Sizes
12-16 days
Manufacturing + testing
With Reversible Actuator
included
Belimo / analogue
Batch of 20 pcs
18-25 days
Batch Production
Delivery to Central Asia
12-18 days
Railway container
Payment Terms
I need the Russian HVAC text to translate. Please provide it.
30% prepayment, 70% before shipment.
Standard
Letter of credit (L/C)
Irrevocable
Recommended for Projects
Warranty & Service
Warranty
2 years
Body & Actuator
Spare Actuators
In Stock
Replacement in 15 minutes
Wiring Diagram
In Russian
For Any Fire Alarm System
Commissioning
Instruction + video
WhatsApp consultation
Ready to order or need a consultation?
Write to us — an engineer will prepare a commercial proposal with a calculation of quantities and exact cost within 24 hours.